Protective clothing
Filter products
This washable Cleanroom Coverall is made from state of the art cleanroom fabric. Material & Properties Material: 98% Polyester / 2% Carbon Colour: light blue Weave structure: 3/2 Twill Basic weight: 120 g/m² ISO 4 Particle filtration 0.3 µm: 99.0% Sleeve cuffs at the arms Press studs on collar and trouser leg Adjustable elastic at the back Cleanroom fabric Autoclavable Possible sterilisation methods: Steam autoclave, gamma irradiation, beta irradiation, ETO Packaging Individually packed
The reusable cleanroom long gown is made from a state-of-the-art cleanroom fabric. Material & properties Material: polyester + carbon Cuffs on the arms Press studs on collar 2-way zip No pockets Colour: White Fabric Warp (polyester filament yarn): 75d Weft (polyester texturised yarn): 100d Conductive yarn, on warp and weft: 20d Weave structure: 3/2 twill Density: 172 x 121 (warp x weft/inch) Weight: 120 g/m² Conductive yarn spacing: 4.5mm x 4.5mm grid Pore size: 20 μm Particle filtration (IES-RP-CC003.2): 99.0% at 0.3 μm 99.4% at 0.5 μm Air permeability (ASTM D 737-1996): 3.1 cc/cm² /sec Water vapour permeability (ASTM E 96-2000): 11.047 g/m² /24h Tensile strength (ASTM D 5304): Warp: 96.4 kg Weft: 83.0 kg Tear strength (ASTM D 2261-1996): Warp: 2.2 kg Weft: 2.1 kg Abrasion resistance (ASTM D 3886-99): 266 Cleanroom class (recommended): ISO 4-5 Friction-related static charge (JIS L 1094-1997): Below 10 V Drop time to 10% of 5,000V: 0.01 sec Surface resistance (ASTM D257): 5.9 x 107 Ω/m² Particle formation released per litre: 4 at 0.3 μm 3 at 0.5 μm Sterilisation compatibility: steam autoclave, gamma radiation, beta radiation, ETO Packaging individually packed
The autoclavable Cleanroom Full Protection Goggles BioClean Clearview BCAG have a super soft frame made of thermoplastic rubber with an indirect ventilation system that provides high wearing comfort and reduces the risk of contaminants entering the controlled. These safety glasses ensure a clear view through hardened, scratch-resistant polycarbonate lenses. Material & Properties Material: Thermoplastic rubber Width: 190 mm Height: 85 mm Depth: 85 mm Glass thickness: 3,1 mm Colour: white ISO 4 GMP A CAT II Autoclavable Super soft frame Indirect ventilation through openings at top and bottom Toughened, scratch-resistant and optically correct polycarbonate glass Lint- and latex-free headband Tested to withstand > 40 autoclave cycles of 30 minutes at 121°C Anti-fog performance is maintained (under laboratory conditions) for up to 25 cycles without degradation. Can be worn over corrective spectacles Packaging 1 piece in a sealed PE bag (must be removed before autoclaving) 12 PE bags in an carton
The reusable bonnet has press studs for attaching the face mask. Material & properties Material: 98 % polyester / 2 % carbon Colour: white or blue Weave structure: 3/2 twill Base weight: 118 g/m² Particle filtration 0.3µm / 0.5 µm ISO 4 EU GMP A - C /US FED Std 10 - 100,000 With press studs at the front 2 press studs for attaching face masks Press studs at the back of the head Pattern: Chequered 5mm * 5mm possible sterilisation methods: Steam autoclave, gamma irradiation Beta irradiation, ETO: steam - gamma Breathability ISO 9237-2:1995: 18.10 l/m² Water impermeability DIN EN ISO 11092:2014 Ret: 2.71 m²Pa/W Tear strength ISO 13934/1:2013: warp 830 N / weft 1500 N Abrasion resistance ISO 12947/2:1998: > 100,000 cycles Decay time EN 1149-3: 0.01 sec Particle retention capacity: 0.3 µm=98%, 0.5 µm=98%, 5.0 µm=98% The reusable garment is made of lightweight micropolyester fabric Maximum washing machine load: 60 % Washing chemicals: anionic / non-ionic, preferably pure anionic agents with good dispersing properties. Maximum pH value: 8 - 8.5. Close the zip and press studs before washing. Pre-wash: Maximum 35°C - 10 minutes Main wash: Maximum 60°C - 15 minutes Cool down 1°C per minute to 50°C to avoid creasing. Rinse ( 2 x ) and neutralise with 1 cc/kg acetic acid 80%, 10 min at 40°C. Last rinse: We recommend an antibacterial and antistatic detergent. Dry gently and slowly. Tumble dry at a maximum of 85°C Application For optimum effectiveness: Try to wear the clothing as closed as possible and try to avoid air holes at the neck. Air formation in the clothing (blow-up effect) must be avoided. Have your cleanroom garments decontaminated and washed in good time to avoid contamination in the cleanroom. Cleanroom garments are not water-repellent and quickly absorb water and chemicals. Small holes and tears should be repaired as quickly as possible (patches). The cleanroom garments should not come into contact with solvents, chemicals, disinfectants and stain removers Maintenance The washing frequency depends on the working environment (microelectronics - pharmaceuticals ...) and the working conditions. The cleanroom garments should be washed in a cleanroom laundry. The maximum washing temperature is 60°C - Do not iron! The addition of chlorine is prohibited in the washing process. Thorough rinsing and neutralisation. A pH value between 5.5 and 6 should be achieved. If dry cleaning is necessary: only with perchloroethylene. A low speed is recommended for tumble drying. Maximum shrinkage: less than 3 % Packaging 1 piece
Cleanroom overshoes (reusable overshoes) made of state of the art cleanroom fabric. High design with a firm non-slip rubber sole. Material & Properties Material: 98% Polyester / 2% Carbon ISO 4 - 8 EU GMP A - C /US FED Std 10 - 100,000 Weight: 118 g/m² Type of antistatic yarn: Negastat P210 Fabric: Twill 3/2 Pattern: Plaid 5mm * 5mm 2 colored straps with 2-piece buckle on front foot over instep, Different colors per size. Combi P sole: TPU sole, gamma and ETO resistant. Excellent slip resistance. Very high slip resistance. With reinforced border from sole end to fabric. Press studs and rubber at the top of the boot shaft Fabric name: Alsistrong Usage: clean room Sterilization: Steam - Gamma Breathability ISO 9237-2:1995: 18.10 l/m².s Water tightness DIN EN ISO 11092:2014 Ret: 2,71 m²Pa/W Tear strength ISO 13934/1:2013: warp 830 N / weft 1500 N Abrasion resistance ISO 12947/2:1998: > 100,000 cycles Decay time EN 1149-3: 0.01 sec Surface resistance EN 1149-1: 10 exp6 Ohm Particle retention: 0.3 µm = 98%, 0.5 µm = 98%, 5.0 µm = 98% The reusable garment is made of lightweight micropolyester fabric.1. maximum washing machine load : 60 %.2. washing chemicals: anionic / non-ionic, preferably pure anionic agents with good dispersing properties.3. maximum pH: 8 - 8.5. close zipper and push buttons before washing.4. prewash: maximum 35°C - 10 minutes5. main wash: maximum 60°C - 15 minutes6. cool down 1°C per minute up to 50°C to avoid wrinkles7. rinse ( 2 x ) and neutralize with 1 cc/kg acetic acid 80%, 10 min at 40°C.8. last rinse: we recommend an antibacterial and antistatic detergent.9. dry gently and slowly.10. Tumble dry at a maximum temperature of 85°C. Application For optimal effectiveness: try to wear clothes as closed as possible and try to avoid air holes at the neck. Air formation in the clothing (blow-up effect) must be avoided. Have your cleanroom clothing decontaminated and washed in time to avoid contamination in the cleanroom. Cleanroom clothing is not water repellent and quickly absorbs water and chemicals. Small holes and tears should be repaired (patched) as soon as possible. Cleanroom clothing should not come into contact with solvents, chemicals, disinfectants and stain removers Maintenace The washing frequency depends on the working environment (microelectronics - pharmaceutical ...) and working conditions. The cleanroom garments should be washed in a cleanroom laundry. The maximum washing temperature is 60°C - Do not iron! The addition of chlorine is prohibited in the washing process. A thorough rinsing and neutralization. A PH- value between 5.5 and 6 should be achieved. If dry cleaning is required: only with perchloroethylene. When drying in a dryer, a low speed is recommended. Maximum shrinkage: less than 3%. Packaging 1 pair
The Univet reusable goggles are uncoated and made entirely of polycarbonate and can be sterilised with steam at 121 degrees for 30 minutes (1ATM). They can be worn over corrective glasses. Ventilation is provided by side protection. Material & Properties Material: Polycarbonate Lens colour: clear Ventilation via side protection can be worn over prescription glasses without metal content Marking frame (EU): U EN166 F CE Lens marking (EU): 2-1.2 U 1 F CE Frame technology: Overspecification Mechanical strength: Low impact energy (F) Scale number: (2-1.2) Standards: EN166, EN170 Optical class: Optical class (1) Sterilisable with steam at 121 degrees for 30 min Packaging 1 piece